 SX Series
Pressure sensors
FEATURES
* 0...1 to 0...300 psi * Absolute, differential and gage devices * High impedance bridge * Low power consumption for battery operation
www..com
GENERAL DESCRIPTION
The SX series of pressure sensors provides the most cost effective method of measuring pressures up to 300 psi. These sensors were specifically designed to be used with non-corrosive and non-ionic media, such as air and dry gases. Convenient pressure ranges are available to measure differential, gage and absolute pressures from 0 to 1 psi (SX01) up to 0 to 300 psi (SX7300D). The absolute (A) devices have an internal vacuum reference and an output voltage proportional to absolute pressure. The differential (D) devices allow application of pressure to either side of the diaphragm and can be used for gage or differential pressure measurements. However, 300 psi (SX7300D) can be applied to pressure port P2 only. Pressure port P1 is able to handle operating pressures up to 150 psi only. This product is packaged either in SenSym's standard low cost chip carrier "button" package, a plastic ported "N" package, a metal TO can package or a dual inline package (DIP). All packages are designed for applications where the sensing element is to be integral to the OEM equipment. Scale: 1 cm 1/2 inch
APPLICATIONS
* Industrial controls * Pneumatic controls * Medical instrumentation * Barometry
EQUIVALENT CIRCUIT
Vs
These packages can be o-ring sealed, epoxied, and/or clamped onto a pressure fitting. A closed bridge 4-pin SIP configuration is provided for electrical connection to the button or "N" package. The TO can offers a 5-pin open bridge configuration. Because of its high-impedance bridge, the SX series is ideal for portable and low power or battery operated systems. Due to its low noise, the SX is an excellent choice for medical and low pressure measurements.
+
Output
ELECTRICAL CONNECTION
Button sensor
GND out + +VS out 1 2 3 4
NC NC
Button sensor or "N" package
Bottom view (open bridge)
Out+ GND +Vs 7 Out6 5 8 1 2 43 NC +Vs P2 vent hole for gage devices only
P1
Vs
+Vs +Vs P2 4 1 out + out GND GND out - out + vent hole 1 P1 4 +Vs out + GND +Vs out 1 P1 P2 4 +Vs +Vs
Output
SXxxxGD2 DIP
SXxxxAD2 SXxxxD4 DIP
+
TO can or DIP package
The polarity indicated is for pressure applied to: SX... : P1 (forward gage) SX...AS/GSO : P1 (forward gage) SX...AD2 : P1 (forward gage) SX...GD2 : P2 (backward gage) SX...DD4 : P2 (backward gage)
March 2004 / 052
1/10
http://www.sensortechnics.com
SX Series
Pressure sensors
PRESSURE SENSOR CHARACTERISTICS
Maximum ratings (for all devices)
Suppy voltage, V S Temperature ranges Operating Storage Maximum pressure at any port11 www..com Lead temperature (soldering 4 sec.) +12 VDC -40C to +85C -55C to +125C 150 psig 250 C Proof pressure10 SX01 SX05 SX15 SX30 SX100 SX150 SX7300 forward gage, P1 SX7300, backward gage, P2 20 psi 20 psi 30 psi 60 psi 150 psi 200 psi 250 psi 500 psi
Part number
SX01... SX05... SX15... SX30... SX100... SX150... SX7300 forward gage SX7300 backward gage
Operating pressure
0 - 1 psid 0 - 5 psid 0 - 15 psi (a) d 0 - 30 psi (a) d 0 - 100 psi (a) d 0 - 150 psi (a) d 0 - 100 psig 0 - 300 psig
Proof pressure 10 Min.
20 psi 20 psi 30 psi 60 psi 150 psi 200 psi 250 psi 500 psi 15 mV 50 mV 75 mV 75 mV 100 mV 75 mV --45 mV
Full scale span Typ.
20 mV 75 mV 110 mV 110 mV 150 mV 110 mV --70 mV
Max.
25 mV 100 mV 150 mV 150 mV 200 mV 150 mV --95 mV
PERFORMANCE CHARACTERISTICS1 SX01, SX05
Characteristics
Temperature coefficient of span6,9 Zero pressure offset TA = 25C12 Temperature coefficient of offset5,9 Combined linearity and hysteresis 3 Long term stability of offset and sensitivity 8 Response time (10 % to 90 %)7 Input resistance TA = 25C Temperature coefficient of resistance6,9 Output impedance Repeatability 4
Min.
-2550 -35 ----------+690 -----
Typ.
-2300 -20 +4 0.2 0.1 0.1 4.65 +750 4.65 0.5
Max.
-2050 0 --0.5 ------+810 -----
Unit
ppm/C mV V/V/C %FS mV ms k ppm/C k %FS
SX15..., SX30..., SX100..., SX150...
Characteristics
Temperature coefficient of span6, 9 Zero pressure offset TA = 25C12 Temperature coefficient of offset5, 9 Combined linearity and hysteresis 3 Long term stability of offset and sensitivity 8 Response time (10% to 90%)7 Input resistance TA = 25C Temperature coefficient of resistance6, 9 Output impedance Repeatability 4
Min.
-2400 -35 ----------+690 -----
Typ.
-2150 -20 +4 0.2 0.1 0.1 4.65 +750 4.5 0.5
Max.
-1900 0 --0.5 ------+810 -----
Unit
ppm/C mV V/V/C %FS mV ms k ppm/C k %FS
2/10
March 2004 / 052
http://www.sensortechnics.com
SX Series
Pressure sensors
SX7300...
Characteristic
Temperature coefficient of span6,9 Zero pressure offset TA = 25C Temperature coefficient of offset5,9 Combined linearity and hysteresis 3 Long term stability of offset and sensitivity 8 Response time (10 % to 90 %)7 Input resistance TA = 25C www..com Temperature coefficient of resistance6,9 Output impedance Repeatability 4
Min
-2400 -40 -------3.0 -------
Typ
-2150 0 +4 0.1 0.1 0.1 4.5 +750 4.65 0.3
Max
-1900 40 --0.5 ----6.0 -------
Unit
ppm/C mV V/V/C %FS mV ms k ppm/C k %FS
TYPICAL PERFORMANCE CHARACTERISTICS
March 2004 / 052
3/10
http://www.sensortechnics.com
SX Series
Pressure sensors
MECHANICAL AND MOUNTING CONSIDERATIONS
Button sensor element The button sensor element was designed to allow easy interface with additional cases and housings which then allow pressure connection. The device can be mounted with an o-ring, gasket, or RTV seals on one or both sides of the device. The device can then be glued or clamped into a variety of fixtures www..com and the leads can be bent as necessary to allow for ease of electrical connection. However, caution is advised as repeated bending of the leads will cause eventual breakage. For most gage applications, pressure should be applied to the top side of the device (see Physical Construction Drawing). For differential applications, the top side of the device (P1) should be used as the high pressure port and the bottom (P2) as the low pressure port (except for SX7300D, where P2 is the high pressure port). The button SX package has a very small internal volume of 0.06 cubic centimeters for P1 and 0.001 cubic centimeters for P2. "N" packaged sensor The "N" packaged sensor is designed for convenient pressure connection and easy PC board mounting. To mount the device horizontally to a PC board, the leads can be bent downward and the package attached to the board using either tie wraps or mounting screws. For pressure attachment, tygon or silicon tubing is recommended. The "N" package version of the sensor has two (2) tubes available for pressure connection. For gage devices, pressure should be applied to port P1. For differential pressure applications, port P1 should be used as the high pressure port and P2 should be used as the low pressure port. TO package The TO package parts are available with pressure access only to P1 for absolute and gage pressure. Therefore, on gage devices the bottom of the TO package must be left open so atmosphere. Typically, tubing is attached directly around the top of the TO can or the package can be glued or o-ring sealed into a fixture. As always care should be taken not to stress the package. For all sensor packages care should be taken not to expose the parts to caustic media. This includes washers for board cleaning, etc..
User calibration
SX series devices feature the button IC pressure sensor element. This will keep overall system costs down by allowing the user to select calibration and temperature compensation circuits which specifically match individual application needs. In most cases, the primary signal conditioning elements to be added to the SX by the user are: offset and span calibration and temperature compensation. Some typical circuits are shown in the application section.
Vacuum reference (absolute devices)
Absolute sensors have a hermetically sealed vacuum reference chamber. The offset voltage on these units is therefore measured at vacuum, 0 psia. Since all pressure is measured relative to a vacuum reference, all changes in barometric pressure or changes in altitude will cause changes in the device output.
GENERAL DISCUSSION
Output characteristics The SX series devices give a voltage output which is directly proportional to applied pressure. The devices will give an increase in positive going output when increasing pressure is applied to pressure port P1 of the device. If the devices are operated in the backward gage mode, the output will increase with decreases in pressure. The devices are ratiometric to the supply voltage. Changes in supply voltage will cause proportional changes in the offset voltage and full-scale span.
Media compatibility
SX devices are compatible with most noncorrosive gases. Because the circuitry is coated with a protective silicon gel (parylene coating for all TO can devices), some otherwise corrosive environments can be compatible with the sensors. As shown in the physical construction diagram below for the button sensor element and ,,N" package, fluids must generally be compatible with silicon gel, RTV, plastic, and aluminum for forward gage use and RTV, silicon, glass and aluminum for backward gage or differential applications. For questions concerning media compatibility, contact the factory.
PHYSICAL CONSTRUCTION
4/10
March 2004 / 052
http://www.sensortechnics.com
SX Series
Pressure sensors
APPLICATION INFORMATION
General
The SX family of pressure sensors functions as a Wheatstone bridge. When pressure is applied to the device (see Figure I) the resistors in the arms of the bridge change by an amount . it can be seen that the sensitivity change with temperature is slightly non-linear and can be correlated very well with an equation of he form: S = SO[(1 - TD) + TD2] (3) where TD is the temperature difference between 25C and the temperature of interest, SO is the sensitivity at 25C, and beta () and rho () are correlation constants. Fortunately, between 0C and 70C the change in sensitivity with temperature is quite linear, and excellent results can be obtained over this temperature range by ignoring the second-order temperature dependent term. Operating outside the 0C and 70C temperature range will require a more rigorous mathematical approach and the use of non-linear compensating circuitry, if accuracy of better than 1 % is required. Because the majority of SX applications fall within the 0C to 70C operating temperature range, the discussion and circuit designs given here will ignore the non-linear effects. Thus: S = SO (1 - TD) (4) Substituting equation (4) into equation (1) and ignoring V OS, it can be shown that the necessary bridge voltage, V B, will be of the form: 2 VB = V BO =V BO [(1 - TD + (TD) +...)] (1-TD) where V BO is the bridge voltage at 25C. This equation is again non-linear. However, for the temperature range of interest, and since is small (0.215%/C from the electrical tables), the above expression can be approximated by: V B=V BO [1 +TD] with less than 1 % error. Thus to compensate for a negative 2150 ppm/C sensitivity change with temperature, the bridge voltage should increase with temperature at a rate of +2150 ppm/C. The above value of bridge voltage change will be used in the circuit discussions that follow. That is to say, the required change in terms of ppm/C is: * VB = +2050 ppm/C VB This term enters into several compensation circuit equations, particularly when the bridge excitation is from a constant current source. To summarize, the following list indicates how the sensor variables can be accommodated * Full-scale span from device to device. Make the gain adjustment in the op amp circuitry * Temperature coefficient of span: 1) temperature compensate the bridge or 2) temperature compensate the op amp gain * Offset voltage: Adjustment in op amp circuitry * Offset voltage temperature coefficient: Usually can be ignored. For more precise design requirements, contact the factory for information on how to compensate for this term.
www..com
Figure I. Button sensor bridge schematic The resulting differential output voltage V 0 is easily shown to be V O= V B x . Since the change in resistance is directly proportional to pressure, V O can be written as: V O = S x P x V B V OS (1) Where: V O is the output voltage in mV S is the sensitivity in mV/V per psi P is the pressure in psi V B is the bridge voltage in volts. V OS is the offset error (the differential output voltage when the applied pressure is zero). The offset voltage presents little problem in most applications, since it can easily be corrected for in the amplifier circuitry, or corrected digitally if a microprocessor is used in the system.
Bridge compensation circuits
Although thermistors can be used to temperature compensate the bridge (and in fact will be required for extended temperature operation), they are inherently non-linear, difficult to use in volume production, and more expensive than the circuit approaches shown here, which use inexpensive semiconductor devices The circuits shown have been designed to incorporate a minimum number of adjustments and allow interchangeability of devices with little variation from device to device. In general, equations for the bridge voltage and its change with temperature are given to enable the user to modify or adjust the circuitry as required. 1. Diode string (Figure II) For systems using 6 V supplies, this method of compensating for the effects of span over temperature is the lowest cost solution The diodes are small signal silicon diodes, such as 1N914 or 1N4148, and do not have to be matched.
Temperature effects
In this discussion, for simplicity of notation, the change of a variable with temperature will be designated with a dot (*) over the variable. For example, * in sensitivity = change in temperature = S change T
S
From equation (1), and ignoring the VOS term, it in seen that for a given constant pressure, the output voltage change, as a function of temperature*, is: * * V O = SPV B (2) Thus, in order for output voltage to be independent of temperature, the voltage across the bridge, V B, must change with temperature in the "opposite direction" from the sensitivity change with temperature. From the typical curves for the temperature dependence of span (span = S x P x V B), March 2004 / 052
()
The bridge input resistance*, R also B changes with temperature and is quite linear in the temperature range of interest. The bridge resistance has a temperature coefficient of typically: * RB = +750 ppm/C RB
()
Figure II. Diode String Span Compensation 5/10
http://www.sensortechnics.com
SX Series
Pressure sensors
APPLICATION INFORMATION (cont.)
a) V B=V S-4 b) VB VB
www..com
( ) = ( VS -4 ) * c) ( = -2500 ppm/C for silicon diodes )
Figure II. Equations For example, solving equation (b) for V B/ V B when V S = 6.0 V = 0.7 V
()
*
a) V B = V S - b)
a)
VB =
(V S + IO R2)
( VB) VB
=
*
=1
( ) x (VS ) -
*
* b) V B = RB (1 - )+ VB RB
()()
=
( )[ ( )]
* IO 1- V S IO VB
c) * d)
R1 + R2
c)
RB R2 + RB
( )=
VS 5V 9V 12V
-2500 ppm/C
* * d) IO = 3360 ppm/C, RB =+750ppm/C IO RB
()
()
Table I. Selected R values vs V S for figure III R1 () 3.32k 4.02k 4.22k R2 () 1.43k 806 604
e)
IO =
67.7 mV R1
The design steps are straight forward: 1) Knowing V S and the desired bridge voltage V B, solve equation (b) for . 2) Now, solve equation (c) for R2, letting RB = 4650. 3) Solve equation (a) for IO. 4) Find R1 or its nearest 1% tolerance value from equation (e). Table II gives specific 1% resistor values in ohms, for several popular system voltages. For best results, the resistors should be 1% metal film with a low temperature coefficient. Table II. Selected R values vs V S for figure IV VS 5V 6V 9V 12V 15V VB 3V 4V 6V 9V 10V R1() 147 105 68.1 43.2 41.2 R2() 11.0k 9.53k 9.53k 8.25k 9.53k
Yields: * VB = 2188 ppm/C VB Since the sensor's span changes with temperature at -2150 ppm/C, this technique will typically result in an overall negative TC of 38 ppm/C. This error is acceptable in most applications. For operation with V S above 6V, it is recommended to use the transistor or constant current compensation technique. 2. Transistor compensation network Figure III uses a single transistor to simulate a diode string, with the equations as shown. The values shown in Table I were found to give excellent results over 0C to 70C. Again, if precision temperature compensation is required for each device, the fixed value resistors shown for R1 in Table I can be replaced by a 3.24k resistor in series with a 1k pot. Then, each devices temperature compensation can be individually adjusted.
3. Constant current excitation (Figure IV) The circuits shown in Figures II and III, although simple and inexpensive, have one drawback in that the voltage across the bridge is determined by the compensation network. That is, the compensation network is determined and what voltage is "leftover" is across the bridge. The circuit of Figure IV solves this problem and allows the bridge voltage to be independently selected. In Figure IV, the bridge is driven from a constant current source, the LM334, which has a very well known and repeatable temperature coefficient of +3300 ppm/ C. This temperature coefficient (TC), in conjunction with the TC of the bridge resistance, is too high to compensate the sensitivity TC, hence resistor R2 is added to reduce the total circuit TC. The basic design steps for this method of temperature compensation are shown below. However, please refer to SenSym's Application Note SSAN-16 for details on the temperature compensation technique.
Amplifier design There are hundreds of instrumentation amplifier designs, and the intent here will be to briefly describe one circuit which: * does not load the bridge * involves minimal components * provides excellent performance Amplifier adjustment procedure 1. Without pressure applied, (a) Short points A and B together as shown in Figure V. Adjust the 1 k common-mode rejection ( C M R R ) pot until the voltage at test point (Tp) V x is equal to the voltage at test point (Tp) V R. This is easily accomplished by placing a digital voltmeter between these test points and adjusting for 0.000.
Figure III. Transistor/Resistor span TC compensation 6/10
Figure IV. Constant current span TC Compensation March 2004 / 052
http://www.sensortechnics.com
SX Series
Pressure sensors
APPLICATION INFORMATION (cont.)
(b) Remove the short and adjust the 500 offset adjust pot until V x is again equal to V R. (c) Adjust the 2k reference (V R) adjust pot to get an output voltage (V O) equal to 1.00V. 2. Apply the fuII-scale pressure and adjust the span adjust pot, R5, to get the output voltage that is desired to represent fullwww..com scale. Table III. For 0 to 70C operation SPAN FS 3V 4V 5V 5V 10V 5V 10V The choice of the operational amplifiers to use is based on individual cost/performance trade-offs. The accuracy will be primarily limited by the amplifier's common-mode rejection, offset voltage drift with temperature and noise performance. Low cost, low performance devices, such as the LM324 can be used if the temperature ranges limited to 25C +15C and an accuracy of +2% is adequate. For more precise applications amplifiers such as the LT1014 and LT1002 have been found to be excellent. An amplifier that uses a single supply is shown in Figure V. Table III gives resistor values for various supply and full-scale output combinations. Factory compensated devices This application note provides the necessary information for temperature compensating and calibrating the SX sensors. In some case, the customer may find that SX devices which have been factory adjusted for temperature compensation and span are more economical for a particular application. SenSym does offer devices with this feature. For more information on these factory calibrated and compensated devices, the SCX series and SDX series, please contact Sensortechnics.
VS 5V 6V 9V 12V 12V 15V 15V
VB 3.5V 4.5V 7V 10V 10V 12V 12V
R2 9.09k 8.45k 7.87k 7.15k 7.15k 7.68k 8.87k
R1 118 86.6 54.9 36.5 36.5 31.6 31.6
R5 604 604 1k 1.82k 511 1.4k 604
Rp 2k 2k 2k 5k 2k 5k 2k
Note: Application information shown here is based on the closed bridge configuration.
A LT1014CN B LM10CN V O = 4[ 1 + 10k ]V IN + V R RG
Figure V: Button Sensor Amplifier Circuit
Resistors labled R3, R4 are 5-Element Resistor Arrays 10 k. Two required
March 2004 / 052
7/10
http://www.sensortechnics.com
SX Series
Pressure sensors
PHYSICAL DIMENSIONS
Button package
www..com
mass: 1 g
dimensions in inches (mm)
N package
mass: 5 g
dimensions in inches (mm)
AHO package (TO-5)
GSO package (TO-39)
mass: 1 g
dimensions in inches (mm)
8/10
March 2004 / 052
http://www.sensortechnics.com
SX Series
Pressure sensors
PHYSICAL DIMENSIONS
Basic sensor DIP "D2" package
www..com
mass: 1 g
dimensions in inches (mm)
Basic sensor DIP "D4" package
3.4 (.135) 6.4 (.250)
mass: 1 g
dimensions in inches (mm)
March 2004 / 052
9/10
http://www.sensortechnics.com
SX Series
Pressure sensors
Specification notes (for all devices):
1. Reference conditions: supply voltage, V S = 5 V DC, TA = 0C to 70C, common-mode line pressure = 0 psig, pressure applied to P1, unless otherwise noted. 2. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. 3. See Definition of Terms. Hysteresis - the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 4. Maximum difference in output at any pressure with the operating pressure range and temperature within 0C to +70C after: a) 100 temperature cycles, 0C to +70C www..com b) 1.0 million pressure cycles, 0 psi to full scale span 5. Slope of the best straigth line from 0C to +70C. 6. This is the best straight line fit for operation between 0C and 70C. For operation outside this temperature, contact factory for more specific applications information. 7. Response time for a 0 psi to full-scale span pressure step change. 8. Long term stability over a one year period . 9. This parameter is not 100 % tested. It is guaranteed by process design and tested on a sample basis only. 10. If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. Note: The proof pressure for the forward gage of all devices in the D4-package and the SX7300 is the specified value or 100 psi, whatever is less. 11. Maximum pressure at any port is the maximum operating plus common-mode pressure which can be applied. 12. The zero pressure offset is 0 mV Min, 20 mV Typ and 35 mV Max for part nos. SXxxxGD2 and SXxxxDD4.
ORDERING INFORMATION
To order, use the following part numbers:
Order part number
Pressure range Absolute Pressure 0 - 15 psi 0 - 30 psi 0 -100 psi 0 -150 psi Gage Pressure 0 - 1 psi 0 - 5 psi 0 -15 psi 0 -30 psi 0 -100 psi 0 -150 psi 0 - 300 psi Differential Pressure 0 - 1 psi 0 - 5 psi 0 -15 psi 0 -30 psi 0 -100 psi 0 -150 psi Button package SX15A SX30A SX100A SX150A use SX01D use SX05D use differential devices SX7300D SX01D SX05D SX15D SX30D SX100D SX150D "N" package SX15AN SX30AN SX100AN --use SX01DN use SX05DN use differential devices --SX01DN SX05DN SX15DN SX30DN SX100DN SX150DN TO metal can package SX15AHO SX30AHO SX100AHO --SX01GSO SX05GSO SX15GSO SX30GSO SX100GSO SX150GSO ----------DIP"D2" package (single ported) SX15AD2 SX30AD2 SX100AD2 --SX01GD2 SX05GD2 SX15GD2 SX30GD2 SX100GD2 ----------------DIP"D4" package (dual ported) ----------------------SX01DD4 SX05DD4 SX15DD4 SX30DD4 SX100DD4 ---
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
10/10
March 2004 / 052
http://www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of SX01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X